Climate Control System

DUPLEX SYSTEM

The advantages of traditional gas and heat pump energy saving equipment include being fuel gas cost effective and heat pump operation energy saving. Not only making the traditional heating mature and reliable, but also meeting the basic needs of CO2 self sufficiency.

 

Parameters

Energy form Model Heating capacity/kW(Standard) Maximum input power kW Maximum heating water temperature ℃ Heating area/㎡(Room temperature/low temperature)
(WWA) MP260PWN2 258 60 60 1200
MP1030PWN2 1028 230 5140
MP1800PWN2 1803 401 9015
MP3940PWN2 3938 875

 

Energy form Model Heating capacity/kW(Standard) Maximum input power kW Air volume(㎡/h) Heating area/㎡(Room temperature/low temperature)
(WA) MP35PWN2 35 7 7000 200
MP38PWN2 38 7.5 8000 220
MP20PWN2 20 5 4000 120
MP25PWN2 25 6 4500 145

 

 

 

 

COP is up to 7.0 cooling and dehumidification Tail-end restriction free

 

WATER/GROUND SOURCE HEAT PUMP SYSTEM

Combined with the project resources, it can be used in the rivers, lakes, shallow groundwater and deep high temperature groundwater in the location of the project for heating, which is not affected by the environment and climate. It has outstanding advantages for projects in extremely cold areas and has significant energy saving effect.

PARAMETERS​

Energy form Model Heating capacity/KW(Room temperature/low temperature) Max. input power kW Max. heating water Temperature ℃ Heating area/㎡(Room temperature/low temperature)
WWA MP260PWN2 258 60 60 1200
MP1030PWN2 1028 230 5140
MP1800PWN2 1803 401 9015
MP3940PWN2 3938 875 20000

Energy form Model Heating capacity/kW(Standard) Maximum input power kW Air volume(㎡/h) Heating area/㎡(Room temperature/low temperature)
(WA) MP35PWN2 35 7 7000 200
MP38PWN2 38 7.5 8000 220
MP20PWN2 20 5 4000 120
MP25PWN2 25 6 4500 145

COP is up to 7.0 cooling and dehumidification Tail-end restriction free
CURTAIN HUMIDIFICATION AND COOLING SYSTEM

Working Principle:

The function of the curtain is divided into internal shading, external shading and internal heat preservation.

Wet Pad Features:

These functions can be opened and closed according to the time, or manually closed. Click the full off button to close the curtain, though the full off button will only take effect when the curtain is inactive.

 

CIRCULATION OF UNIFORM TEMPERATURE SYSTEM

Working Principle:

Ventilation is divided into top window ventilation and outside ventilation.

Optional:

Both ventilation modes can be controlled by setting the switch time period, and the windows can also be manually operated.

 

Level Circulation

Vertical Circulation